Created on 11/06/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
SXCB
Atmospherically referenced, direct-acting sequence valve without reverse flow
check
SERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-13A
Atmospherically referenced, direct-acting sequence valves will supply a secondary circuit with flow once the
pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of this sequence valve controls
the pressure at port 1 relative to the atmospheric vent.
TECHNICAL DATA
Factory Pressure Settings Established at 30 cc/min.
Maximum Operating Pressure 350 bar
Response Time - Typical 2 ms
Maximum Valve Leakage at Reseat 0,7 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting 4
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-010-007
Seal kit - Cartridge Polyurethane: 990-010-002
Seal kit - Cartridge Viton: 990-010-006
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
K Handknob
(A)ADJUSTMENT RANGE
A 500 - 3000 psi (35 - 210 bar), 1000 psi
(70 bar) Standard Setting
B 300 - 1500 psi (20 - 105 bar), 1000 psi
(70 bar) Standard Setting
C 2000 - 6000 psi (140 - 420 bar), 2000
psi (140 bar) Standard Setting
D 200 - 800 psi (14 - 55 bar), 400 psi (28
bar) Standard Setting
E 100 - 400 psi (7 - 28 bar), 200 psi (14
bar) Standard Setting
W 800 - 4500 psi (55 - 315 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/SXCB
TECHNICAL FEATURES
Suitable for use in load holding applications.
Atmospherically referenced valves should only be used where it is impossible have a drain connection. Over time, the atmospherically referenced valves may leak
externally or allow moisture into the spring chamber.
Approximately 1 drop (0,07 cc) of fluid will pass into the vented spring chamber every 4000 cycles.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
Model Code Example: SXCBLANCONFIGURATION OPTIONS
Created on 11/06/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2